ABS - American Building Supply, Inc.
Monday, November 20, 2017 -

 


Construction - Specifications: Molded Panel Mineral Core 45-60 Minute

Specifications: 3 Ply construction. Meets or exceeds industry standards of WDMA I.S.1 Testing Standards ASTM-E-152, CSFM 43.7, CAN4-S104, NFPA-252, UBC-7-2-97, UL10C
Lay Up Method: Bond and Sand
Maximum Sizes: Width - 3/0 Length - 7/0
Thickness: 1-3/4” ONLY
Stiles: Laminated Composite to wood (Georgia Pacific), Specific to rating*
Rails: Laminated Composite to wood (Georgia Pacific), Specific to rating* Width = 1” Minimum
Core: Gypsum Mineral
Fire Rating: 45-60 Minute Rated*
Faces: Primed Molded Panel Single Ply
Adhesive: Type-1 PVA, Interior installation only.
Machining: To Specification
Lites: N/A
Louvers: N/A
Temp Rise: 30 Minutes 250 Degrees maximum.
Acoustical Rating: 29 STC Operable (With seal / Pemko S773)
Warranty: Standard Two year. See limited warranty for details.
Description Abbreviations: MC-45NP = Mineral Core 45 Minute, Neutral Pressure; MC-45B = Mineral Core 45 Minute, Category B; MC-45A = Mineral Core 45 Minute, Category A; MC-60NP = Mineral Core 60 Minute, Neutral Pressure; MC-60B = Mineral Core 60 Minute, Category B; MC-60A = Mineral Core 60 Minute, Category A
Recommended Use: Light Commercial

*See fire door specifications section in catalogue for details on sizes, hardware and construction limitations.

Maximum Sizes
NP
PP Cat-B
PP Cat-A
Single Swing 3/0 X 7/0 3/0 X 7/0 3/0 X 7/0
3 Point Reg. Pair 6/0 X 7/0 6/0 X 7/0 6/0 X 7/0
4 Point Reg. Pair 6/0 X 7/0 6/0 X 7/0 6/0 X 7/0



       

.